{"product_id":"autel-maxihvac-ac909d","title":"Autel MaxiHVAC AC909D A\/C Diagnostic System | US Version","description":"\u003cstyle\u003e\n  .ac909d-description .image-with-text img {\n    display: block;\n    max-width: 100%;\n    height: auto;\n    margin-bottom: 10px;\n  }\n\n  @media only screen and (min-width: 768px) {\n    .ac909d-description .image-with-text {\n      display: flex;\n      align-items: center;\n      gap: 20px;\n    }\n\n    .ac909d-description .image-with-text img {\n      flex: 0 0 auto;\n      width: 50%;\n    }\n\n    .ac909d-description .text-section {\n      flex: 1;\n      min-width: 0;\n    }\n  }\n\u003c\/style\u003e\n\n\u003cdiv class=\"ac909d-description\"\u003e\n\n  \u003cdiv class=\"image-with-text\"\u003e\n    \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/0573\/4698\/files\/MaxiHVAC_AC909_HVAC_service_platform-1.png?v=1792176719\" alt=\"Autel MaxiHVAC AC909 A\/C and thermal management diagnostic platform\" width=\"1280\" height=\"1280\" loading=\"lazy\"\u003e\n\n    \u003cdiv class=\"text-section\"\u003e\n      \u003ch3\u003eAutel AC909D A\/C \u0026amp; Thermal Management Diagnostics\u003c\/h3\u003e\n      \u003cul\u003e\n        \u003cli\u003e\n          The Autel MaxiHVAC AC909D combines vehicle diagnostic data\n          with physical A\/C measurements to help technicians investigate\n          cooling complaints and evaluate system performance. This listing\n          is for the North American AC909D package in the MaxiHVAC AC909\n          product line.\n        \u003c\/li\u003e\n        \u003cli\u003e\n          By bringing refrigerant-circuit measurements and supported\n          vehicle data together, the system helps technicians assess\n          faults before deciding which components need further testing\n          or replacement.\n        \u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n\n  \u003cdiv class=\"image-with-text\"\u003e\n    \u003cdiv class=\"text-section\"\u003e\n      \u003ch3\u003eIntelligent Guided Diagnostic Workflow\u003c\/h3\u003e\n      \u003cul\u003e\n        \u003cli\u003e\n          Illustrated, step-by-step instructions guide technicians\n          through equipment connections and diagnostic procedures.\n          Vehicle-specific A\/C information helps identify component\n          specifications and locations on supported applications.\n        \u003c\/li\u003e\n        \u003cli\u003e\n          A graphical analysis screen brings together live pressures,\n          temperatures, humidity and supported OBD sensor data.\n          Technicians can compare related readings to better understand\n          how the refrigerant circuit and electronic controls interact.\n        \u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n\n    \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/0573\/4698\/files\/Connected_AC_Measurement_Tools.jpg?v=1792176714\" alt=\"Guided automotive A\/C diagnostic workflow illustration\" width=\"1280\" height=\"1280\" loading=\"lazy\"\u003e\n  \u003c\/div\u003e\n\n \n  \u003cdiv class=\"image-with-text\"\u003e\n    \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/0573\/4698\/files\/AC909_nitrogen_leak_testing-2.png?v=1792176719\" alt=\"Nitrogen leak testing and vacuum verification illustration\" width=\"1280\" height=\"1280\" loading=\"lazy\"\u003e\n\n    \u003cdiv class=\"text-section\"\u003e\n      \u003ch3\u003eNitrogen Leak Testing \u0026amp; Micron-Level Vacuum Verification\u003c\/h3\u003e\n      \u003cul\u003e\n        \u003cli\u003e\n          Guided nitrogen testing supports system tightness checks before\n          evacuation and charging. The North American AC909D package\n          includes a NAVAC Bluetooth vacuum pump and digital micron gauge.\n        \u003c\/li\u003e\n        \u003cli\u003e\n          Live micron-level readings stream directly to the tablet.\n          Automated decay testing helps technicians evaluate vacuum\n          performance and moisture removal using measured data rather\n          than evacuation time alone.\n        \u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n\n  \u003cdiv class=\"image-with-text\"\u003e\n    \u003cdiv class=\"text-section\"\u003e\n      \u003ch3\u003eCompressor Testing \u0026amp; Component Analysis\u003c\/h3\u003e\n      \u003cul\u003e\n        \u003cli\u003e\n          On supported applications, variable-displacement compressors\n          can be evaluated through OBD bi-directional commands or direct\n          compressor-control testing while monitoring low- and high-side\n          pressures.\n        \u003c\/li\u003e\n        \u003cli\u003e\n          Dedicated diagnostic procedures also address evaporators,\n          condensers, metering devices and system blockages. The\n          manifold's backlit sight glass supports visual refrigerant\n          inspection for contamination or debris that may require\n          further investigation.\n        \u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n\n    \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/0573\/4698\/files\/Compressor_Testing_Component_Analysis.jpg?v=1792176714\" alt=\"Automotive compressor and A\/C system analysis illustration\" width=\"1280\" height=\"1280\" loading=\"lazy\"\u003e\n  \u003c\/div\u003e\n\n  \n  \u003cdiv class=\"image-with-text\"\u003e\n    \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/0573\/4698\/files\/Connected_A_C_Diagnostic_Tools-3.png?v=1792176720\" alt=\"Connected A\/C measurement tools and diagnostic functions illustration\" width=\"1280\" height=\"1280\" loading=\"lazy\"\u003e\n\n    \u003cdiv class=\"text-section\"\u003e\n      \u003ch3\u003eConnected A\/C Measurement Tools\u003c\/h3\u003e\n      \u003cul\u003e\n        \u003cli\u003e\n          The modular system combines a diagnostic tablet and MaxiFlash\n          VCI with a four-port manifold, refrigerant scale, compressor\n          box and wireless measurement accessories.\n        \u003c\/li\u003e\n        \u003cli\u003e\n          Bluetooth temperature clamps measure refrigerant-line\n          temperatures, while temperature and humidity probes provide\n          ambient, cabin and vent readings. These measurements help\n          technicians relate physical system conditions to the vehicle\n          data shown on the tablet.\n        \u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n\n  \u003cdiv class=\"image-with-text\"\u003e\n    \u003cdiv class=\"text-section\"\u003e\n      \u003ch3\u003eBuilt for Modern Vehicle Thermal Management\u003c\/h3\u003e\n      \u003cul\u003e\n        \u003cli\u003e\n          The AC909D is designed for electronically controlled A\/C\n          systems and supported hybrid, EV and heat-pump applications.\n          Available functions depend on the vehicle, application and\n          installed software.\n        \u003c\/li\u003e\n        \u003cli\u003e\n          Before ordering, email\n          \u003ca href=\"mailto:support@autel-us.com\" style=\"color: #ed1c24; text-decoration: underline;\"\u003esupport@autel-us.com\u003c\/a\u003e\n          with the vehicle year, make, model, refrigerant type,\n          existing A\/C equipment and the work you need to perform.\n          We can help check the package and application before purchase.\n        \u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n\n    \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0896\/0573\/4698\/files\/Nitrogen_Leak_Testing_Micron-Level_Vacuum_Verification.jpg?v=1792176714\" alt=\"Hybrid and electric vehicle thermal management illustration\" width=\"1280\" height=\"1280\" loading=\"lazy\"\u003e\n  \u003c\/div\u003e\n\n\u003c\/div\u003e","brand":"Autel","offers":[{"title":"AC909D US Ver","offer_id":52969872523562,"sku":null,"price":9450.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0896\/0573\/4698\/files\/Autel-us-AC909D-1.webp?v=1792217013","url":"https:\/\/autel-us.com\/products\/autel-maxihvac-ac909d","provider":"autel-us.com","version":"1.0","type":"link"}